Cluster Controller with 1 Antenna module - IPS housing
Physical Specifications
Cluster Controller Module (CCM) in plastic housing
Lenght : 185.5 mm (7.3 in)
Width : 98.5 mm (3.88 in)
Height : 57 mm (2.28 in)
Approximate Weight : 211 g (7.44 oz.)
Housing Material : Polycarbonate
Colour : Black
Antenna Reader Module (ARM) in plastic housing
Lenght : 185.5 mm (7.3 in)
Width : 98.5 mm (3.88 in)
Height : 57 mm (2.28 in)
Approximate Weight : 266 g (9.38 oz.)
Housing Material : Polycarbonate
Colour : Black
Electrical Specifications - CCM
Power
Input voltage : 10 to 15 V DC
(Polarity Sensitive) : (13.8V Battery powered apllication)
Power Requirements Current (mA) Power (W)
12 V DC with no : 140 1.7
peripherals connected
Power Input Protection : Reverse polarity and over-current
protection are provided.
Peripheral Communications Ports
Clustering Feature : Up to 8 Expansion Modules may be
(Baud Rate 115 200) plugged side-to-side and into the CCM.
S-Bus (Host) : This allows Expansion Modules (like the
(Baud Rate 9 600 ARM) and other S-Bus Devices to be
installed up to 150m from the CCM.A
maximum of eight devices may be
connected via S-Bus.
Host Computer : Standard Ethernet RJ45 connector.
10/100 Base T, half or full duplex,
Proprietary Protocol
RS485 Door Controller : RS485, 38 400 Baud, 8 data bits, no parity,
Maximum 64 Addresses 1 stop bit, Secure communications Protocol
Provision is made for line termination
RS485 System Controller : RS485, 38 400 Baud, 8 data bits, no parity,
Maximum 64 Addresses 1 stop bit, Secure Communications Protocol
(Only in IXP 220 mode.) Provision is made for line termination
Real Time Clock Backup Battery (RTC)
Battery Type : 1 x 3 V, CR2032, Lithium cell battery.
Battery Life : 2 Years with power OFF
: 5 years with power ON
: 5 years storage with Battery Tab in place.
Processor
Type : 32/bit ARM Cortex M3
Operating at 180 MHz
Total RAM : 200 Byte.
Flash : 16 M Byte.
Other
Anti-tamper Switch : 1PCB Mounted Micro-lever Switch.
Electrical Specifications - Antenna Reader Module
Power
Input Voltage : 12 V DC to 15 V DC,
(polarity sensitive) when
powered separately as
necessary for a remote,
S-Bus installation
Power Requirements Current (mA) Power (W)
Input Voltage 12 V DC with : 50 0.6
no Antennas attached
Input Voltage 12 V DC with : 200 2.4
Antennas attached
Power Input Protection : Reverse polarity, and
Transient voltage
protection is provided
Relay Power Requirements : An additional ~0.4 W per Relay in use
Communications
Direct : When the ARM is plugged (side-by-side)
(Baud Rate 115 200 directly into a cluster, or in the IPS Housing
option.
S-Bus : S-Bus allows for the remote installation of
(Baud Rate:9600) the ARM, up to 150m away from its CCM.
Module Status : Slave
Reader Options
Antenna Port : 2 Fully functional Antenna Reader Ports.
Digital Inputs
Input Type : 2 Dry-contact inputs with End-of-line (EOL)
Sensing and 2 Dry-contact inputs without
End-of-line (EOL) Sensing.
Detection Resistance Range : < 2 kOhm
Protection Range : +15 v continuous.
Relays
Relay Output : 2 Independent, single-pole, double-throw
(SPDT) Relays, each with NO, COM and NC
contacts.
Contact Ratings : 10 A at 28 V DC
5 A at 220 V AC
12 A at 120 V AC
Operations : 100 000 Minimum
Processor
Type : ARM Cortex M0 operating at 45MHz
Total RAM : 4 K Byte
Flash : 48 K Byte
Other
Anti-tamper Switch : 1 Internal Switch